Original file line number | Diff line number | Diff line change |
---|---|---|
|
@@ -43,6 +43,9 @@ | |
INSTANTANEOUS_CURRENT_L1 = r'^\d-\d:31\.7\.0.+?\r\n' | ||
INSTANTANEOUS_CURRENT_L2 = r'^\d-\d:51\.7\.0.+?\r\n' | ||
INSTANTANEOUS_CURRENT_L3 = r'^\d-\d:71\.7\.0.+?\r\n' | ||
FUSE_THRESHOLD_L1 = r'^\d-\d:31\.4\.0.+?\r\n' # Applicable when current limitation is active | ||
FUSE_THRESHOLD_L2 = r'^\d-\d:51\.4\.0.+?\r\n' # Applicable when current limitation is active | ||
FUSE_THRESHOLD_L3 = r'^\d-\d:71\.4\.0.+?\r\n' # Applicable when current limitation is active | ||
TEXT_MESSAGE_CODE = r'^\d-\d:96\.13\.1.+?\r\n' | ||
TEXT_MESSAGE = r'^\d-\d:96\.13\.0.+?\r\n' | ||
DEVICE_TYPE = r'^\d-\d:24\.1\.0.+?\r\n' | ||
|
@@ -66,8 +69,48 @@ | |
ACTUAL_SWITCH_POSITION = r'^\d-\d:96\.3\.10.+?\r\n' | ||
VALVE_POSITION_GAS = r'^\d-\d:24\.4\.0.+?\r\n' | ||
|
||
# Multiple 'slaves' can be linked to the main device. | ||
# The type is reported on 24.1.0 | ||
# Specifications are in EN 13757-3 | ||
# For example: Water mater = 7, Gas meter = 3 | ||
# Identifier is on 96.1.0 (in NL for ex) or | ||
# on 96.1.1 (in BE for ex) | ||
# The values are reported on 24.2.1 | ||
# With an exception in Belgium for the GAS meter | ||
# Be aware that for the gas volume, another OBIS-code is published | ||
# than the one listed in section 7 of DSMR P1. | ||
# This is due to the fact that in Belgium the not-temperature | ||
# corrected gas volume is used while in the Netherlands, | ||
# the temperature corrected gas volume is used. | ||
MBUS1_DEVICE_TYPE = r'^\d-1:24\.1\.0.+?\r\n' | ||
MBUS1_EQUIPMENT_IDENTIFIER = r'^\d-1:96\.1\.0.+?\r\n' | ||
MBUS1_EQUIPMENT_IDENTIFIER_ALT = r'^\d-1:96\.1\.1.+?\r\n' | ||
MBUS1_VALVE_POSITION = r'^\d-1:24\.4\.0.+?\r\n' | ||
MBUS1_METER_READING = r'^\d-1:24\.2\.1.+?\r\n' | ||
MBUS1_METER_READING_ALT = r'^\d-1:24\.2\.3.+?\r\n' | ||
|
||
MBUS2_DEVICE_TYPE = r'^\d-2:24\.1\.0.+?\r\n' | ||
MBUS2_EQUIPMENT_IDENTIFIER = r'^\d-2:96\.1\.0.+?\r\n' | ||
MBUS2_EQUIPMENT_IDENTIFIER_ALT = r'^\d-2:96\.1\.1.+?\r\n' | ||
MBUS2_VALVE_POSITION = r'^\d-2:24\.4\.0.+?\r\n' | ||
MBUS2_METER_READING = r'^\d-2:24\.2\.1.+?\r\n' | ||
MBUS2_METER_READING_ALT = r'^\d-2:24\.2\.3.+?\r\n' | ||
|
||
MBUS3_DEVICE_TYPE = r'^\d-3:24\.1\.0.+?\r\n' | ||
MBUS3_EQUIPMENT_IDENTIFIER = r'^\d-3:96\.1\.0.+?\r\n' | ||
MBUS3_EQUIPMENT_IDENTIFIER_ALT = r'^\d-3:96\.1\.1.+?\r\n' | ||
MBUS3_VALVE_POSITION = r'^\d-3:24\.4\.0.+?\r\n' | ||
MBUS3_METER_READING = r'^\d-3:24\.2\.1.+?\r\n' | ||
MBUS3_METER_READING_ALT = r'^\d-3:24\.2\.3.+?\r\n' | ||
|
||
MBUS4_DEVICE_TYPE = r'^\d-4:24\.1\.0.+?\r\n' | ||
MBUS4_EQUIPMENT_IDENTIFIER = r'^\d-4:96\.1\.0.+?\r\n' | ||
MBUS4_EQUIPMENT_IDENTIFIER_ALT = r'^\d-4:96\.1\.1.+?\r\n' | ||
MBUS4_VALVE_POSITION = r'^\d-4:24\.4\.0.+?\r\n' | ||
MBUS4_METER_READING = r'^\d-4:24\.2\.1.+?\r\n' | ||
MBUS4_METER_READING_ALT = r'^\d-4:24\.2\.3.+?\r\n' | ||
|
||
# TODO 17.0.0 | ||
# TODO 96.3.10 | ||
|
||
ELECTRICITY_USED_TARIFF_ALL = ( | ||
ELECTRICITY_USED_TARIFF_1, | ||
|
@@ -88,38 +131,6 @@ | |
BELGIUM_CURRENT_AVERAGE_DEMAND = r'^\d-\d:1\.4\.0.+?\r\n' | ||
BELGIUM_MAXIMUM_DEMAND_MONTH = r'^\d-\d:1\.6\.0.+?\r\n' | ||
BELGIUM_MAXIMUM_DEMAND_13_MONTHS = r'^\d-\d:98\.1\.0.+?\r\n' | ||
BELGIUM_MAX_POWER_PER_PHASE = r'^\d-\d:17\.0\.0.+?\r\n' # Applicable when power limitation is active | ||
BELGIUM_MAX_CURRENT_PER_PHASE = r'^\d-\d:31\.4\.0.+?\r\n' # Applicable when current limitation is active | ||
|
||
# Multiple 'slaves' can be linked to the main device. | ||
# Mostly MBUS1 = GAS METER with values on 24.2.3 | ||
# While WATER METER reports it's values on 24.2.1 | ||
# The GAS METER also reports its valve state on 24.4.0 | ||
# Dev type for gas = 7 and water = 8 | ||
BELGIUM_MBUS1_DEVICE_TYPE = r'^\d-1:24\.1\.0.+?\r\n' | ||
BELGIUM_MBUS1_EQUIPMENT_IDENTIFIER = r'^\d-1:96\.1\.1.+?\r\n' | ||
BELGIUM_MBUS1_VALVE_POSITION = r'^\d-1:24\.4\.0.+?\r\n' | ||
BELGIUM_MBUS1_METER_READING1 = r'^\d-1:24\.2\.1.+?\r\n' | ||
BELGIUM_MBUS1_METER_READING2 = r'^\d-1:24\.2\.3.+?\r\n' | ||
|
||
BELGIUM_MBUS2_DEVICE_TYPE = r'^\d-2:24\.1\.0.+?\r\n' | ||
BELGIUM_MBUS2_EQUIPMENT_IDENTIFIER = r'^\d-2:96\.1\.1.+?\r\n' | ||
BELGIUM_MBUS2_VALVE_POSITION = r'^\d-2:24\.4\.0.+?\r\n' | ||
BELGIUM_MBUS2_METER_READING1 = r'^\d-2:24\.2\.1.+?\r\n' | ||
BELGIUM_MBUS2_METER_READING2 = r'^\d-2:24\.2\.3.+?\r\n' | ||
|
||
BELGIUM_MBUS3_DEVICE_TYPE = r'^\d-3:24\.1\.0.+?\r\n' | ||
BELGIUM_MBUS3_EQUIPMENT_IDENTIFIER = r'^\d-3:96\.1\.1.+?\r\n' | ||
BELGIUM_MBUS3_VALVE_POSITION = r'^\d-3:24\.4\.0.+?\r\n' | ||
BELGIUM_MBUS3_METER_READING1 = r'^\d-3:24\.2\.1.+?\r\n' | ||
BELGIUM_MBUS3_METER_READING2 = r'^\d-3:24\.2\.3.+?\r\n' | ||
|
||
Comment on lines
-91
to
-116
There was a problem hiding this comment. Choose a reason for hiding this commentThe reason will be displayed to describe this comment to others. Learn more. Removing these might be breaking for anyone using these. There was a problem hiding this comment. Choose a reason for hiding this commentThe reason will be displayed to describe this comment to others. Learn more. Correct. But backwards compatibility is not really an issue. You always depend on a specific version. |
||
BELGIUM_MBUS4_DEVICE_TYPE = r'^\d-4:24\.1\.0.+?\r\n' | ||
BELGIUM_MBUS4_EQUIPMENT_IDENTIFIER = r'^\d-4:96\.1\.1.+?\r\n' | ||
BELGIUM_MBUS4_VALVE_POSITION = r'^\d-4:24\.4\.0.+?\r\n' | ||
BELGIUM_MBUS4_METER_READING1 = r'^\d-4:24\.2\.1.+?\r\n' | ||
BELGIUM_MBUS4_METER_READING2 = r'^\d-4:24\.2\.3.+?\r\n' | ||
|
||
|
||
LUXEMBOURG_EQUIPMENT_IDENTIFIER = r'^\d-\d:42\.0\.0.+?\r\n' # Logical device name | ||
|
||
|
@@ -142,5 +153,3 @@ | |
EON_HU_INSTANTANEOUS_REACTIVE_POWER_Q2 = r'^\d-\d:6\.7\.0.+?\r\n' | ||
EON_HU_INSTANTANEOUS_REACTIVE_POWER_Q3 = r'^\d-\d:7\.7\.0.+?\r\n' | ||
EON_HU_INSTANTANEOUS_REACTIVE_POWER_Q4 = r'^\d-\d:8\.7\.0.+?\r\n' | ||
EON_HU_MAX_POWER_ON_L2 = r'^\d-\d:51\.4\.0.+?\r\n' | ||
EON_HU_MAX_POWER_ON_L3 = r'^\d-\d:71\.4\.0.+?\r\n' |
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
May be these can be generic matching all devices:
The exiting references are generic too. The regex will simple give more matches if there are more devices.
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
Afaik there can only be a specific regex per value you want to parse. Otherwise it will only match the first one.