-
Notifications
You must be signed in to change notification settings - Fork 45
TUNING
This guide is intended for system administrators to optimize Construct and maximize its performance for their environment. This does not cover BUILD tuning, and it is expected that Construct is already installed and the SETUP has been completed.
-
Some instructions may reference Construct's configuration system. This is accessed via the administrator's console which can be reached by striking
ctrl-c (SIGINT)
and then using theconf
command (see:help conf
). The console can also be reached interactively through your preferred client in the!control
room. Alternatively, configuration state can be manipulated directly through the!conf
room. Configuration changes take effect as a result of state events sent to the!conf
room, thus all aforementioned methods to change configuration are the same. -
CHANGES TO CONFIGURATION ARE EFFECTIVE IMMEDIATELY. ERRONEOUS VALUES MAY CAUSE UNEXPECTED BEHAVIOR AND RESULT IN PROGRAM TERMINATION. CONFIGURATION ERRORS MAY ALSO PREVENT STARTUP. Please see the TROUBLESHOOTING guide for how to recover from configuration errors.
It is highly recommended these items are reviewed by administrators before continuing with the remainder of this guide.
The most impactful actions an administrator can take come from providing Construct with a suitable I/O environment. The server's workload relies heavily on random-access to local files. Using a low-latency solid-state-drive (SSD) rather than a high-latency mechanical hard-disk (HD) is preferred but not required for great performance. When using a low-latency storage device, the impact from this section is much less pronounced, but adherence to it is still advised nonetheless. When using high-latency storage devices, adhering to this section is essential.
-
Operating system must support asynchronous filesystem I/O. Currently, only Linux is viable as Construct makes use of the AIO interface. We note that while FreeBSD and Windows actually have superior asynchronous IO support, we simply haven't ported to those within Construct yet and this section will be updated. On Linux, there are incremental benefits which Construct takes advantage of between Linux 4.4 and Linux 5.3. Always use the newest possible kernel for best performance.
-
Filesystem must support Direct-IO. Ext4 and family support Direct-IO (
O_DIRECT
). Many experimental filesystems do not support Direct-IO including ZFS (with the exception of some very recent releases). It is strongly advised you place your database directory in a filesystem which fully supports Direct-IO. It is important that Construct does not read data through the operating system's page-cache. Direct-IO allows the server to submit many fine-grained read requests to high-latency storage in parallel without impeding execution. -
Hardware device properties must be detected. Construct probes information about block devices using
sysfs(5)
. It must acquire the device's queue depth, and a few other characteristics for optimal operation. When not found, the queue depth defaults to32
. This value controls the request parallelism and may be incorrectly utilizing the backplane. For multi-disk RAID arrays, it is often too low and bandwidth is wasted. For limited virtual machines and cheaper hardware it may be too high, causingio_submit(2)
to block, stalling the server.- Review device information with the console command
fs dev
. If detected device information is incorrect or absent, manually configure the appropriate queue depth with the environment variableircd_fs_aio_max_events
before execution.
- Review device information with the console command
-
RocksDB must support parallel Direct-IO reads. Construct takes advantage of features incrementally between RocksDB v5.18 through
v6.10.2 (and beyond)*. Unfortunately many distributions ship with RocksDB v5.17.2 (including Ubuntu 20.04) which lacks several features that maximize performance. When Construct is built with--with-included-rocksdb
it defaults to v6.6.4 (matching Debian stable) which is recommended if possible. At the time of this writing, parallel Direct-IO reads have only recently landed in the RocksDB master branch and not any tagged release. This feature is significant enough for our workload that we preemptively advise configuring with the next tagged release--with-included-rocksdb=v6.XX.X
once it is available to maximize peformance.- RocksDB 6.10.1 through 6.11.X have a bug and cannot be used. Please check for 6.12, otherwise you must use an older version.
Construct automatically detects jemalloc(3)
on the system at ./configure
time (see: BUILD) and marks it as DT_NEEDED
on ELF systems to load it as the default allocator. Do not LD_PRELOAD
jemalloc as this will override our configuration and increases memory usage.
- Confirm jemalloc in use at the console with the command:
mem get version string
.
On Linux systems (or systems which support mlock2(2)
), and when jemalloc(3)
is used, and when RocksDB 5.18+ is used, Construct has a feature which can prevent swapping of database caches by locking them into RAM. To enable this feature, the resource limit for locked memory must be set to unlimited
. This can be achieved by running ulimit -l unlimited
before executing. Note that any limit on locked memory (even if larger than the cache sizes) will disable this feature.
A page-fault for swapped data will block the entire server until the data is read back into RAM. This is inferior to Construct's normal operation which reads data from the disk asynchronously without blocking. There is never a good reason to swap cache data; it is always better to simply drop it. In the future, Construct will support trimming caches under high memory pressure as reported by Linux Pressure-Stall-Information.
Most of Construct's runtime footprint in RAM consists of a cache of Matrix events read from the database. The data in many of these events may be directly accessed for fundamental server operations; for example, a client's access-token and user information is stored with events in special server rooms. The event cache is a set of LRU (Least Recently Used) caches. The size of these caches should be tuned to at least the "working-set size" expected by the server. If these caches are too small, load will be placed on the next storage tier. For storage devices with poor random access characteristics it is important these caches cover the server's working-set size.
To list the event cache information, try the following commands (example output shown):
> db cache events *
COLUMN PCT HITS MISSES INSERT CACHED CAPACITY INSERT TOTAL LOCKED
* 61.94% 18742243 3818637 3814446 1.41 GiB (1517280856) 2.28 GiB (2449473536) 4.46 GiB (4787594200) 4.41 MiB (4628512)
> db cache events **
COLUMN PCT HITS MISSES INSERT CACHED CAPACITY INSERT TOTAL LOCKED
content 17.85% 2113271 85256 83255 22.85 MiB (23962992) 128.00 MiB (134217728) 569.37 MiB (597026848) 0.00 B (0)
depth 90.71% 11292 96431 96431 58.06 MiB (60876968) 64.00 MiB (67108864) 59.68 MiB (62575248) 0.00 B (0)
event_id 9.24% 191518 153523 153523 5.92 MiB (6202768) 64.00 MiB (67108864) 865.07 MiB (907093240) 0.00 B (0)
origin_server_ts 99.99% 9852 566483 566258 64.00 MiB (67103832) 64.00 MiB (67108864) 353.29 MiB (370455584) 0.00 B (0)
room_id 99.99% 1015939 216695 216694 63.99 MiB (67102496) 64.00 MiB (67108864) 132.05 MiB (138467768) 1.93 MiB (2019088)
sender 39.18% 56357 80879 80879 50.16 MiB (52592768) 128.00 MiB (134217728) 50.36 MiB (52809616) 0.00 B (0)
state_key 40.49% 7336 89035 87181 25.91 MiB (27171856) 64.00 MiB (67108864) 383.42 MiB (402049648) 0.00 B (0)
type 99.92% 1716885 66485 66485 31.97 MiB (33527264) 32.00 MiB (33554432) 40.69 MiB (42667312) 0.00 B (0)
_event_idx 99.99% 652575 505956 505955 255.98 MiB (268418416) 256.00 MiB (268435456) 635.40 MiB (666268064) 23.45 KiB (24016)
_room_events 62.14% 308312 13144 13144 79.54 MiB (83405864) 128.00 MiB (134217728) 79.73 MiB (83608112) 284.73 KiB (291560)
_room_joined 52.73% 2087968 6789 6789 4.22 MiB (4422936) 8.00 MiB (8388608) 4.23 MiB (4431280) 0.00 B (0)
_room_state 25.40% 2038549 21590 21590 16.25 MiB (17044504) 64.00 MiB (67108864) 52.26 MiB (54793600) 0.00 B (0)
_room_head 26.41% 7986 9435 9435 2.11 MiB (2215192) 8.00 MiB (8388608) 37.56 MiB (39389688) 0.00 B (0)
_event_json 62.79% 82254 1166164 1166153 642.96 MiB (674189112) 1024.00 MiB (1073741824) 736.76 MiB (772552224) 3.52 MiB (3690824)
_event_refs 79.17% 54501 112508 112505 50.67 MiB (53127080) 64.00 MiB (67108864) 68.76 MiB (72098088) 0.00 B (0)
_event_type 99.77% 22 8215 8215 15.96 MiB (16738848) 16.00 MiB (16777216) 17.27 MiB (18109240) 73.93 KiB (75704)
_event_sender 0.00% 0 23453 23453 0.00 B (0) 16.00 MiB (16777216) 15.01 MiB (15739768) 0.00 B (0)
_event_horizon 99.96% 15722 18296 18296 15.99 MiB (16769768) 16.00 MiB (16777216) 18.91 MiB (19833200) 0.00 B (0)
_room_state_space 67.24% 3997 24712 24712 86.06 MiB (90241400) 128.00 MiB (134217728) 92.28 MiB (96762256) 0.00 B (0)
To view the configuration item for the size of a cache, which should match your
output from the above command, use the following command where <COLUMN>
is
replaced by one of the names under COLUMN
in the above output:
conf ircd.m.dbs.<COLUMN>.cache.size
To alter a cache size, set the configuration item with a byte value. In the
example below we will set the _event_json
cache size to 256 MiB. This change
will take effect immediately and the cache will grow or shrink to that size.
conf set ircd.m.dbs._event_json.cache.size 268435456
Tip: The best metric to figure out which caches are inadequate is not necessarily the utilization percentage. Caches that are too small generally exhibit high values under
INSERT TOTAL
as well as full utilization. If this value is several times higher than the cache size and growing, consider increasing that cache's size.
(TODO)