bessere Beschreibung der Parameter für SAJ-H2 aktive Batteriesteuerung #624

Closed
wants to merge 4 commits into from
Closed
Show file tree
Hide file tree
Changes from all commits
Commits
File filter

Filter by extension

Filter by extension

Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
18 changes: 9 additions & 9 deletions templates/release/de/meter/saj-h2_0.yaml
Original file line number Diff line number Diff line change
Expand Up @@ -49,9 +49,9 @@ render:
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
defaultmode: 2 # optional
minsoc: 20 # Ladung mit maximaler Geschwindigkeit bis zu dem angegeben Ladestand unabhängig PV-Erzeugung, wenn der Lademodus nicht auf 'Aus' steht (optional)
maxsoc: 95 # optional
defaultmode: 2 # backup_mode, Wert bitte nicht ändern, erforderlich für die aktive Batteriesteuerung - Laden aus dem Netz
minsoc: 20 # Notstromkapazität, auf diesen Wert wird der Speicher eingestellt bei "Entladesperre aus" bzw. "Entladesperre nicht aktiv" (optional)
maxsoc: 95 # Notstromkapazität, ab diesem SOC-Wert und kleiner wird die Entladesperre aktiv bei "Entladesperre ein" (optional)
- usage: pv
default: |
type: template
Expand Down Expand Up @@ -99,9 +99,9 @@ render:
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
defaultmode: 2 # optional
minsoc: 20 # Ladung mit maximaler Geschwindigkeit bis zu dem angegeben Ladestand unabhängig PV-Erzeugung, wenn der Lademodus nicht auf 'Aus' steht (optional)
maxsoc: 95 # optional
defaultmode: 2 # backup_mode, Wert bitte nicht ändern, erforderlich für die aktive Batteriesteuerung - Laden aus dem Netz
minsoc: 20 # Notstromkapazität, auf diesen Wert wird der Speicher eingestellt bei "Entladesperre aus" bzw. "Entladesperre nicht aktiv" (optional)
maxsoc: 95 # Notstromkapazität, ab diesem SOC-Wert und kleiner wird die Entladesperre aktiv bei "Entladesperre ein" (optional)
- usage: battery
default: |
type: template
Expand Down Expand Up @@ -150,6 +150,6 @@ render:
host: 192.0.2.2 # Hostname
port: 502 # Port
capacity: 50 # Akkukapazität in kWh (optional)
defaultmode: 2 # optional
minsoc: 20 # Ladung mit maximaler Geschwindigkeit bis zu dem angegeben Ladestand unabhängig PV-Erzeugung, wenn der Lademodus nicht auf 'Aus' steht (optional)
maxsoc: 95 # optional
defaultmode: 2 # backup_mode, Wert bitte nicht ändern, erforderlich für die aktive Batteriesteuerung - Laden aus dem Netz
minsoc: 20 # Notstromkapazität, auf diesen Wert wird der Speicher eingestellt bei "Entladesperre aus" bzw. "Entladesperre nicht aktiv" (optional)
maxsoc: 95 # Notstromkapazität, ab diesem SOC-Wert und kleiner wird die Entladesperre aktiv bei "Entladesperre ein" (optional)
18 changes: 9 additions & 9 deletions templates/release/de/meter/saj-h2_1.yaml
Original file line number Diff line number Diff line change
Expand Up @@ -49,9 +49,9 @@ render:
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
defaultmode: 2 # optional
minsoc: 20 # Ladung mit maximaler Geschwindigkeit bis zu dem angegeben Ladestand unabhängig PV-Erzeugung, wenn der Lademodus nicht auf 'Aus' steht (optional)
maxsoc: 95 # optional
defaultmode: 2 # backup_mode, Wert bitte nicht ändern, erforderlich für die aktive Batteriesteuerung - Laden aus dem Netz
minsoc: 20 # Notstromkapazität, auf diesen Wert wird der Speicher eingestellt bei "Entladesperre aus" bzw. "Entladesperre nicht aktiv" (optional)
maxsoc: 95 # Notstromkapazität, ab diesem SOC-Wert und kleiner wird die Entladesperre aktiv bei "Entladesperre ein" (optional)
- usage: pv
default: |
type: template
Expand Down Expand Up @@ -99,9 +99,9 @@ render:
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
defaultmode: 2 # optional
minsoc: 20 # Ladung mit maximaler Geschwindigkeit bis zu dem angegeben Ladestand unabhängig PV-Erzeugung, wenn der Lademodus nicht auf 'Aus' steht (optional)
maxsoc: 95 # optional
defaultmode: 2 # backup_mode, Wert bitte nicht ändern, erforderlich für die aktive Batteriesteuerung - Laden aus dem Netz
minsoc: 20 # Notstromkapazität, auf diesen Wert wird der Speicher eingestellt bei "Entladesperre aus" bzw. "Entladesperre nicht aktiv" (optional)
maxsoc: 95 # Notstromkapazität, ab diesem SOC-Wert und kleiner wird die Entladesperre aktiv bei "Entladesperre ein" (optional)
- usage: battery
default: |
type: template
Expand Down Expand Up @@ -150,6 +150,6 @@ render:
host: 192.0.2.2 # Hostname
port: 502 # Port
capacity: 50 # Akkukapazität in kWh (optional)
defaultmode: 2 # optional
minsoc: 20 # Ladung mit maximaler Geschwindigkeit bis zu dem angegeben Ladestand unabhängig PV-Erzeugung, wenn der Lademodus nicht auf 'Aus' steht (optional)
maxsoc: 95 # optional
defaultmode: 2 # backup_mode, Wert bitte nicht ändern, erforderlich für die aktive Batteriesteuerung - Laden aus dem Netz
minsoc: 20 # Notstromkapazität, auf diesen Wert wird der Speicher eingestellt bei "Entladesperre aus" bzw. "Entladesperre nicht aktiv" (optional)
maxsoc: 95 # Notstromkapazität, ab diesem SOC-Wert und kleiner wird die Entladesperre aktiv bei "Entladesperre ein" (optional)
18 changes: 9 additions & 9 deletions templates/release/en/meter/saj-h2_0.yaml
Original file line number Diff line number Diff line change
Expand Up @@ -49,9 +49,9 @@ render:
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
defaultmode: 2 # optional
minsoc: 20 # Immediate charging with maximum power up to the defined state of charge independently from solar production if the charge mode is not set to 'Off' (optional)
maxsoc: 95 # optional
defaultmode: 2 # backup_mode, please do not change the value, required for active battery control - charging from grid
minsoc: 20 # emergency power capacity, the system is set to this value when "discharge lock off" or "discharge lock not active" (optional)
maxsoc: 95 # Emergency power capacity, from this SOC value and lower, the discharge lock becomes active with "discharge lock on" (optional)
- usage: pv
default: |
type: template
Expand Down Expand Up @@ -99,9 +99,9 @@ render:
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
defaultmode: 2 # optional
minsoc: 20 # Immediate charging with maximum power up to the defined state of charge independently from solar production if the charge mode is not set to 'Off' (optional)
maxsoc: 95 # optional
defaultmode: 2 # backup_mode, please do not change the value, required for active battery control - charging from grid
minsoc: 20 # emergency power capacity, the system is set to this value when "discharge lock off" or "discharge lock not active" (optional)
maxsoc: 95 # Emergency power capacity, from this SOC value and lower, the discharge lock becomes active with "discharge lock on" (optional)
- usage: battery
default: |
type: template
Expand Down Expand Up @@ -150,6 +150,6 @@ render:
host: 192.0.2.2 # Hostname
port: 502 # Port
capacity: 50 # Battery capacity in kWh (optional)
defaultmode: 2 # optional
minsoc: 20 # Immediate charging with maximum power up to the defined state of charge independently from solar production if the charge mode is not set to 'Off' (optional)
maxsoc: 95 # optional
defaultmode: 2 # backup_mode, please do not change the value, required for active battery control - charging from grid
minsoc: 20 # emergency power capacity, the system is set to this value when "discharge lock off" or "discharge lock not active" (optional)
maxsoc: 95 # Emergency power capacity, from this SOC value and lower, the discharge lock becomes active with "discharge lock on" (optional)
18 changes: 9 additions & 9 deletions templates/release/en/meter/saj-h2_1.yaml
Original file line number Diff line number Diff line change
Expand Up @@ -49,9 +49,9 @@ render:
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
defaultmode: 2 # optional
minsoc: 20 # Immediate charging with maximum power up to the defined state of charge independently from solar production if the charge mode is not set to 'Off' (optional)
maxsoc: 95 # optional
defaultmode: 2 # backup_mode, please do not change the value, required for active battery control - charging from grid
minsoc: 20 # emergency power capacity, the system is set to this value when "discharge lock off" or "discharge lock not active" (optional)
maxsoc: 95 # Emergency power capacity, from this SOC value and lower, the discharge lock becomes active with "discharge lock on" (optional)
- usage: pv
default: |
type: template
Expand Down Expand Up @@ -99,9 +99,9 @@ render:
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
defaultmode: 2 # optional
minsoc: 20 # Immediate charging with maximum power up to the defined state of charge independently from solar production if the charge mode is not set to 'Off' (optional)
maxsoc: 95 # optional
defaultmode: 2 # backup_mode, please do not change the value, required for active battery control - charging from grid
minsoc: 20 # emergency power capacity, the system is set to this value when "discharge lock off" or "discharge lock not active" (optional)
maxsoc: 95 # Emergency power capacity, from this SOC value and lower, the discharge lock becomes active with "discharge lock on" (optional)
- usage: battery
default: |
type: template
Expand Down Expand Up @@ -150,6 +150,6 @@ render:
host: 192.0.2.2 # Hostname
port: 502 # Port
capacity: 50 # Battery capacity in kWh (optional)
defaultmode: 2 # optional
minsoc: 20 # Immediate charging with maximum power up to the defined state of charge independently from solar production if the charge mode is not set to 'Off' (optional)
maxsoc: 95 # optional
defaultmode: 2 # backup_mode, please do not change the value, required for active battery control - charging from grid
minsoc: 20 # emergency power capacity, the system is set to this value when "discharge lock off" or "discharge lock not active" (optional)
maxsoc: 95 # Emergency power capacity, from this SOC value and lower, the discharge lock becomes active with "discharge lock on" (optional)