Skip to content

Commit

Permalink
Templates update for nightly evcc-io/evcc@9a0d650
Browse files Browse the repository at this point in the history
  • Loading branch information
naltatis committed Sep 8, 2024
1 parent a18d7d7 commit f919be0
Show file tree
Hide file tree
Showing 12 changed files with 372 additions and 8 deletions.
4 changes: 0 additions & 4 deletions templates/nightly/de/meter/kostal-plenticore_0.yaml
Original file line number Diff line number Diff line change
Expand Up @@ -28,8 +28,6 @@ render:
host: 192.0.2.2 # Hostname
port: 1502 # Port
endianness: little # optional
minsoc: 25 # Ladung mit maximaler Geschwindigkeit bis zu dem angegeben Ladestand unabhängig PV-Erzeugung, wenn der Lademodus nicht auf 'Aus' steht (optional)
maxsoc: # optional
watchdog: 60s # optional
- usage: battery
default: |
Expand All @@ -54,6 +52,4 @@ render:
port: 1502 # Port
endianness: little # optional
capacity: 50 # Akkukapazität in kWh (optional)
minsoc: 25 # Ladung mit maximaler Geschwindigkeit bis zu dem angegeben Ladestand unabhängig PV-Erzeugung, wenn der Lademodus nicht auf 'Aus' steht (optional)
maxsoc: # optional
watchdog: 60s # optional
146 changes: 146 additions & 0 deletions templates/nightly/de/meter/saj-h2_1.yaml
Original file line number Diff line number Diff line change
@@ -0,0 +1,146 @@
product:
brand: Ampere
description: Ampere.StoragePro
render:
- usage: grid
default: |
type: template
template: saj-h2
usage: grid
# RS485 via adapter (Modbus RTU)
modbus: rs485serial
id: 1
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
baudrate: 115200 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
comset: "8N1" # Kommunikationsparameter für den Adapter
# RS485 via TCP/IP (Modbus RTU)
modbus: rs485tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
# Modbus TCP
modbus: tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
advanced: |
type: template
template: saj-h2
usage: grid
# RS485 via adapter (Modbus RTU)
modbus: rs485serial
id: 1
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
baudrate: 115200 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
comset: "8N1" # Kommunikationsparameter für den Adapter
# RS485 via TCP/IP (Modbus RTU)
modbus: rs485tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
# Modbus TCP
modbus: tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
- usage: pv
default: |
type: template
template: saj-h2
usage: pv
# RS485 via adapter (Modbus RTU)
modbus: rs485serial
id: 1
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
baudrate: 115200 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
comset: "8N1" # Kommunikationsparameter für den Adapter
# RS485 via TCP/IP (Modbus RTU)
modbus: rs485tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
# Modbus TCP
modbus: tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
advanced: |
type: template
template: saj-h2
usage: pv
# RS485 via adapter (Modbus RTU)
modbus: rs485serial
id: 1
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
baudrate: 115200 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
comset: "8N1" # Kommunikationsparameter für den Adapter
# RS485 via TCP/IP (Modbus RTU)
modbus: rs485tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
# Modbus TCP
modbus: tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
- usage: battery
default: |
type: template
template: saj-h2
usage: battery
# RS485 via adapter (Modbus RTU)
modbus: rs485serial
id: 1
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
baudrate: 115200 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
comset: "8N1" # Kommunikationsparameter für den Adapter
# RS485 via TCP/IP (Modbus RTU)
modbus: rs485tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
# Modbus TCP
modbus: tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
advanced: |
type: template
template: saj-h2
usage: battery
# RS485 via adapter (Modbus RTU)
modbus: rs485serial
id: 1
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
baudrate: 115200 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
comset: "8N1" # Kommunikationsparameter für den Adapter
# RS485 via TCP/IP (Modbus RTU)
modbus: rs485tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
# Modbus TCP
modbus: tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
capacity: 50 # Akkukapazität in kWh (optional)
7 changes: 7 additions & 0 deletions templates/nightly/de/meter/slimmelezer_0.yaml
Original file line number Diff line number Diff line change
Expand Up @@ -8,3 +8,10 @@ render:
template: slimmelezer
usage: grid
host: 192.0.2.2 # IP-Adresse oder Hostname
advanced: |
type: template
template: slimmelezer
usage: grid
host: 192.0.2.2 # IP-Adresse oder Hostname
scale: 1000 # Verwenden Skala von 1000 für Zuidwijk Slimmelezer.
Verwenden Skala 1 für ESPHome DSMR und mhendriks P1 Dongle
7 changes: 7 additions & 0 deletions templates/nightly/de/meter/slimmelezer_1.yaml
Original file line number Diff line number Diff line change
Expand Up @@ -8,3 +8,10 @@ render:
template: slimmelezer
usage: grid
host: 192.0.2.2 # IP-Adresse oder Hostname
advanced: |
type: template
template: slimmelezer
usage: grid
host: 192.0.2.2 # IP-Adresse oder Hostname
scale: 1000 # Verwenden Skala von 1000 für Zuidwijk Slimmelezer.
Verwenden Skala 1 für ESPHome DSMR und mhendriks P1 Dongle
17 changes: 17 additions & 0 deletions templates/nightly/de/meter/slimmelezer_2.yaml
Original file line number Diff line number Diff line change
@@ -0,0 +1,17 @@
product:
brand: mhendriks
description: P1 dongle
render:
- usage: grid
default: |
type: template
template: slimmelezer
usage: grid
host: 192.0.2.2 # IP-Adresse oder Hostname
advanced: |
type: template
template: slimmelezer
usage: grid
host: 192.0.2.2 # IP-Adresse oder Hostname
scale: 1000 # Verwenden Skala von 1000 für Zuidwijk Slimmelezer.
Verwenden Skala 1 für ESPHome DSMR und mhendriks P1 Dongle
9 changes: 9 additions & 0 deletions templates/nightly/de/meter/vzlogger_0.yaml
Original file line number Diff line number Diff line change
Expand Up @@ -18,3 +18,12 @@ render:
port: 8081 # Port (optional)
uuid:
scale: 1 # Multipliziere Rohwert mit diesem Faktor (optional)
l1currentuuid: # optional
l2currentuuid: # optional
l3currentuuid: # optional
l1poweruuid: # optional
l2poweruuid: # optional
l3poweruuid: # optional
l1voltageuuid: # optional
l2voltageuuid: # optional
l3voltageuuid: # optional
4 changes: 0 additions & 4 deletions templates/nightly/en/meter/kostal-plenticore_0.yaml
Original file line number Diff line number Diff line change
Expand Up @@ -28,8 +28,6 @@ render:
host: 192.0.2.2 # Hostname
port: 1502 # Port
endianness: little # optional
minsoc: 25 # Immediate charging with maximum power up to the defined state of charge independently from solar production if the charge mode is not set to 'Off' (optional)
maxsoc: # optional
watchdog: 60s # optional
- usage: battery
default: |
Expand All @@ -54,6 +52,4 @@ render:
port: 1502 # Port
endianness: little # optional
capacity: 50 # Battery capacity in kWh (optional)
minsoc: 25 # Immediate charging with maximum power up to the defined state of charge independently from solar production if the charge mode is not set to 'Off' (optional)
maxsoc: # optional
watchdog: 60s # optional
146 changes: 146 additions & 0 deletions templates/nightly/en/meter/saj-h2_1.yaml
Original file line number Diff line number Diff line change
@@ -0,0 +1,146 @@
product:
brand: Ampere
description: Ampere.StoragePro
render:
- usage: grid
default: |
type: template
template: saj-h2
usage: grid
# RS485 via adapter (Modbus RTU)
modbus: rs485serial
id: 1
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
baudrate: 115200 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
comset: "8N1" # Kommunikationsparameter für den Adapter
# RS485 via TCP/IP (Modbus RTU)
modbus: rs485tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
# Modbus TCP
modbus: tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
advanced: |
type: template
template: saj-h2
usage: grid
# RS485 via adapter (Modbus RTU)
modbus: rs485serial
id: 1
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
baudrate: 115200 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
comset: "8N1" # Kommunikationsparameter für den Adapter
# RS485 via TCP/IP (Modbus RTU)
modbus: rs485tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
# Modbus TCP
modbus: tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
- usage: pv
default: |
type: template
template: saj-h2
usage: pv
# RS485 via adapter (Modbus RTU)
modbus: rs485serial
id: 1
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
baudrate: 115200 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
comset: "8N1" # Kommunikationsparameter für den Adapter
# RS485 via TCP/IP (Modbus RTU)
modbus: rs485tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
# Modbus TCP
modbus: tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
advanced: |
type: template
template: saj-h2
usage: pv
# RS485 via adapter (Modbus RTU)
modbus: rs485serial
id: 1
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
baudrate: 115200 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
comset: "8N1" # Kommunikationsparameter für den Adapter
# RS485 via TCP/IP (Modbus RTU)
modbus: rs485tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
# Modbus TCP
modbus: tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
- usage: battery
default: |
type: template
template: saj-h2
usage: battery
# RS485 via adapter (Modbus RTU)
modbus: rs485serial
id: 1
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
baudrate: 115200 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
comset: "8N1" # Kommunikationsparameter für den Adapter
# RS485 via TCP/IP (Modbus RTU)
modbus: rs485tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
# Modbus TCP
modbus: tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
advanced: |
type: template
template: saj-h2
usage: battery
# RS485 via adapter (Modbus RTU)
modbus: rs485serial
id: 1
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
baudrate: 115200 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
comset: "8N1" # Kommunikationsparameter für den Adapter
# RS485 via TCP/IP (Modbus RTU)
modbus: rs485tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
# Modbus TCP
modbus: tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
capacity: 50 # Battery capacity in kWh (optional)
7 changes: 7 additions & 0 deletions templates/nightly/en/meter/slimmelezer_0.yaml
Original file line number Diff line number Diff line change
Expand Up @@ -8,3 +8,10 @@ render:
template: slimmelezer
usage: grid
host: 192.0.2.2 # IP address or hostname
advanced: |
type: template
template: slimmelezer
usage: grid
host: 192.0.2.2 # IP address or hostname
scale: 1000 # Use scale of 1000 for Zuidwijk Slimmelezer.
Use scale 1 for ESPHome DSMR and mhendriks P1 Dongle
Loading

0 comments on commit f919be0

Please sign in to comment.