Electrical M2M software to get an Electrical Bill approximation

Notifications You must be signed in to change notification settings

crised/electrical

Folders and files

NameName
Last commit message
Last commit date

Latest commit

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Repository files navigation

electrical

Intel NUC working as expected, CentOS 6.4 x86_64

3 Instances are up & running:

23.21.60.18 -> JBoss 23.21.96.77 -> Httpd 107.21.233.48 -> Syslog-ng

Electrical M2M software to get an Electrical Bill approximation

EJB, CDI, Entities, JAX-RS, Arquillian.

AngularJS in the front of the RESTFul API.

PostgreSQL on backend.

We will move to Java EE 7 eventually.

Link to the docs: https://docs.google.com/document/d/1LruXabD3js1uMHJbjtgtn_96fUXqv3CeVnnnc7lMAeA/edit?usp=sharing

Read Variables from Meter

Modbus RTU Frame Format. Not Modbus TCP. 32 bit values (2 Registers, form one float/double) ByteBuffer to be used here. (Java uses two Complement... We might have an issue here?)

Cache Values

1 Second Phase Values Starting register: 13.952

  • +0,1 V1 Voltage
  • +2,3 V2 Voltage
  • +4,5 V3 Voltage

1 Second Total Values Starting register: 14.336

  • +0,1 Total kW
  • +6,7 Total PF

Persistent Values

Power Demands Integrated in 15` Starting Register: 14.592

  • +12,13 kW Import Block Demand
  • +14,15 kvar Import Block Demand
  • +16,17 kVA block Demand

Total Energy Starting Register 14.720

  • +0,1 kWh import

Phase Energies Starting Register 14848

  • +0,1 kWh import L1
  • +2,3 kWh import L2
  • +4,5 kWh import L3

Angular JS Front End

Instant Values

These might be refreshed every 2 minutes, not neccesary 2 store all of them in DB. These reading are important, because customer can know if the power is "ON" on his industry. These can be just one line:

V1 = 220 V,V2 = 220 V,V3 = 230 V 1 Second Total Power 1 Second Total PF

Have a calendar selector, that can be used to select range of days. default is only present day. Need some kind of overlay or similar to show comments, in each variable.

Main Accordion

This resembles the electrical bill:

  • Energy: KWh for the range, e.g. 670 KWh
  • Maximum Total Active Power for the Range:, e.g. 200 KW
  • Maximum Total Active Power in between 18:00 - 23:00
  • Power Factor: This is Calculated at the maximum power divided by the "matching" apparent power. P/S In the same time interval.

Total Detail Accordion

AVG, MIN, MAX for:

  • Active/Reactive/Apparent total Power (3 variables)

Table Accordion

  • Energy Phase 1 (Last sample - Initial Sample)
  • Energy Phase 2
  • Energy Phase 3

Drop Down select one menu:AVG, MIN, MAX Drop Down select one phase: Phase 1, Phase 2, Phase 3. 3 Rows: Voltage, Current, Apparent Power (multiplication of the past and divive by 1000 to get kVA).
(Had to delete active and reactive PowerS because meter is not giving 15' Power Factor for each phase, we can calculate this in the future so I would keep the select buttons.)