Notifications
You must be signed in to change notification settings - Fork 19.3k
New issue
Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.
By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.
Already on GitHub? Sign in to your account
M485 command for RS485 support in Marlin #25680
M485 command for RS485 support in Marlin #25680
Conversation
Co-authored-by: Justin Nesselrotte <[email protected]>
Everything looks good to me! I moved the new config options to the same section as the other serial ports, removed the need to define |
@@ -204,3 +204,6 @@ | |||
#define LUMEN_AUX3_PWM2 PB9 | |||
#define LUMEN_AUX3_A1 PA0 | |||
#define LUMEN_AUX3_A2 PA1 | |||
|
|||
#define RS485_TX_ENABLE_PIN PD11 | |||
#define RS485_RX_ENABLE_PIN PD12 |
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
Another 'burning question'…. Is a board required to have RS485-specific hardware, with specific pins assigned to it? If that is the case, then we can sanity-check the RS485_SERIAL
port number and make sure it corresponds to the required hardware port.
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
Just my 2c. This is the first time I see a RX enable pin on 485 serial communications, isn't it a resources waste?
RS485 is half duplex then you are transmitting you may not receive, then a master to slave protocol should be implemented, then to correclty handle communications answers, just purge RX buffer after TX.
I'm wrong or am I missing something ?
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
Is a board required to have RS485-specific hardware, with specific pins assigned to it?
Yep!
If that is the case, then we can sanity-check the RS485_SERIAL port number and make sure it corresponds to the required hardware port.
I'm not sure how to do that and my need your help.
@GMagician "resource waste" is always debatable. The code this PR uses already has a controller/peripheral protocol. Our long term goal is to make it so not even that is required and we can do cool things like having an autoreporter automatically report up to the host when there's a valid RS485 message, even if that isn't a response to an M485 command. So we're fine with the "waste" as it is now.
fdd2a52
to
f5a905a
Compare
Not sure how important this is, but I don't think this works with G-code compression in OpenPnP, which removes all spaces. When the data to send begins with a decimal digit (e.g. |
Repo: https://github.com/Jnesselr/RS485/
Yep. We did test it extensively, but yes if you have either "remove comments" or "compress gcode" on in OpenPnP, then it will screw this up. Remove comments is unfortunately more aggressive than just removing the comments themselves and does the same code as "compress gcode" here. They're honestly just not worth having it on, given the amount of data going through. |
Also, @thinkyhead, I'm not 100% sure why it's failing. The errors I'm seeing:
I'm not 100% sure why this is failing. It looks like the original failure started with a merged branch and now MarlinCore.cpp is conflicting. I'll look into it more and do some more debugging, but I'm hoping the issue is something obvious to you since I'm not in a state where I can compile and test this code and it visually looks correct to me. |
To make it easier for control programs to parse RS-485 responses, it'd be nice for the various messages this can print to be self-consistent and consistent with the
Compared to i2c:
I propose the following:
|
Note that messages starting with "Error:" may cause hosts like OctoPrint to halt and disconnect. If that is not desired behavior, messages should not start with "Error:". We now have the option to emit a less severe |
I get the feeling we're arriving at the station. In ten, nine, eight, … |
We're definitely close, but still need to go over a couple of things. @theacodes (Sorry, completely missed your message) I'd really like to avoid changing the output that is given with the rs485-reply, but mostly because of the extra work on the OpenPnP side. We already have OpenPnP regex reading off of that, and changing it here would require us to do a lot more work there to handle different types of replies. See here for the regex. We don't currently handle some of the other error conditions directly, we use OpenPnP retries to manage them. If you can help figure out how to make the rs485 regex work in OpenPnP and @sphawes is okay with the support burden of that (meaning helping customers ensure what Marlin sends and what OpenPnP receives is the same), I'm game for it. Best guess would be The warning vs error thing is a little interesting to me. We don't go through OctoPrint for this, but I can understand why this functionality may eventually be something that's used through OctoPrint. Right now, other commands I looked at do send back errors but only if their input is bad. So some of our responses should still be errors, but the |
I am hesitant to tie implementation details here to OpenPnP, since it won't be the only host program using this functionality. @sphawes and I can write documentation for folks when they update their Lumen mobo FW. My biggest concern with the output formats is just being consistent and being easy to match without having to do nested matching- the main problem being I know I said I didn't want to tie this to the implementation details of any one consumer, but just as an illustration- the code from our internal internal tool, Glimmer, looks like this: def _decode_response(line: str) -> bytes:
prefix, rest = line.split(":", 1)
rest = rest.strip()
match prefix:
case "rs485-reply":
if rest == "TIMEOUT":
raise RS485TimeoutError()
try:
return bytes.fromhex(rest)
except ValueError as err:
raise RS485ReadError(...) from err
case "rs485-unexpected-packet":
raise RS485UnexpectedPacketError(...)
case "Error":
raise RS485WriteError(rest)
case _:
raise RS485Error(...) Where my preference would be this: def _decode_response(line: str) -> bytes:
prefix, rest = line.split(":", 1)
rest = rest.strip()
match prefix:
case "rs485-reply":
try:
return bytes.fromhex(rest)
except ValueError as err:
raise RS485ReadError(...) from err
case "rs485-timeout":
raise RS485TimeoutError()
case "rs485-unexpected-packet":
raise RS485UnexpectedPacketError(...)
case "rs485-error":
raise RS485WriteError(...)
case _:
raise RS485Error(...) |
I'm ok with needing to tie a Marlin version to a certain OpenPnP vacuum actuator read regex. It's a pretty simple copy-paste to update, and as long as we change both in lock-step, most folks will never encounter the difference. I definitely prefer to try to standardize our response format in an easy to parse way instead of preserving the current OpenPnP configuration. |
If you do want to preserve a regex for the old pattern and also recognize the new pattern, I'm happy to help. I'm one of those mad nerds who enjoys making things like fancy regexes, proper CSS, and elaborate pseudo-justifications. |
I believe we've sorted out the remaining questions about the protocol changes in this PR. If there are no other concerns I'll go ahead and merge this today. |
Please hold off just a little longer. Several of us are at Open Sauce and Stephen needs to make a couple of small changes more. |
thank you for waiting to merge @thinkyhead! I talked through the implications of changing the format with @Jnesselr and @theacodes, and I think that it would be pretty frustrating for users if we change the response format. it's not just a simple regex change in OpenPnP as i thought in my previous comment; it would actually require a new build of OpenPnP to handle the new format correctly. I propose we go back to the format in f1afaa1. @thinkyhead if this is acceptable to you, i can revert the format but keep your other changes and we can merge. |
Will there be future updates to OpenPnP to allow for a different protocol format and additional features? If so, we should add a version specifier. The option How about that idea? |
That sounds great to us. Thank you @thinkyhead! I'll take my best crack at implementing this for your review if that works. |
You could do that! (or ask ChatGPT to do it….) I can go ahead and whip together the skeleton of the idea now, and then you should go ahead and adjust it to your preferences. |
I haven't run that commit's code, but quick check and it looks correct. Not sure what defaults should be. |
@thinkyhead thank you, I've just tested this in OpenPnP with protocol 1 and it works as expected. I'm all good for this to merge whenever! Thank you so much for your tremendous help getting this in, Scott. |
Description
RS485 is a bus specification, similar to a CAN bus. It uses a differential pair to transmit data. We're using Marlin for the Lumen PnP and controlling it through OpenPnP. Marlin mostly acts as a passthrough here, sending the data to the RS485 bus and listening for responses or timing out.
This PR:
RS485_ENABLED
line define to enable or disable this feature.Most of this PR is around making sure the serial port is set up correctly. Most of the logic involved is in the M485 command itself or in our library.
Requirements
This requires a board that has an RS485 transceiver such as the Opulo's motherboard for the Lumen PNP. This is to support feeders more than anything, right now. You can see more about the feeders here: https://docs.opulo.io/feeders/1-overview/feeder-overview/
Benefits
This adds the M485 command to send RS485 packets and receive responses. Currently it's hardcoded to be the Photon firmware's packet format, but the idea is for that to be changeable, we just weren't sure how best to implement it and decided against doing so until there are other examples.
One nice aspect to this is that the only thing Marlin cares about is whether the packet that goes back to the host is well formatted, matches checksums, etc. It itself does not generate any packet data. See the OpenPnP PR below for more info.
Configurations
Configurations pending PR to configurations repo.
Related Issues
OpenPnP PR: openpnp/openpnp#1539
Photon Firmware (runs on the feeder): https://github.com/photonfirmware/photon