Usermod INA219 Current, Voltage & Power Sensor #4237

Open
wants to merge 7 commits into
base: main
Choose a base branch
from
Open
Show file tree
Hide file tree
Changes from all commits
Commits
File filter

Filter by extension

Filter by extension

Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
132 changes: 132 additions & 0 deletions usermods/INA219/Readme.md
Original file line number Diff line number Diff line change
@@ -0,0 +1,132 @@
# INA219 WLED Usermod

This Usermod integrates the INA219 sensor with WLED to monitor energy consumption. It can read voltage, current, power, and calculate daily, monthly and total energy usage.

## Features

- Monitors bus voltage, shunt voltage, current, and power.
- Calculates total energy consumed in kilowatt-hours (kWh).
- Supports MQTT publishing of sensor data.
- Publishes energy data to Home Assistant for easy integration.
- Displays daily, monthly and total energy used in the WLED GUI under the info section.
- Configurable through WLED's web interface.

## Screenshots

| Info screen | Settings page | Home Assistant |
|------------------------------------------------|-----------------------------------------------------------------|------------------------------------------------------------|
| ![Info screen](./img/info.png "Info screen") | ![Settings page](./img/usermod_settings.png "Settings page") | ![Settings page](./img/homeassistant.png "Home Assistant") |

## Configuration Parameters

| Parameter | Description | Default Value | Possible Values |
|-------------------------------|------------------------------------------------------------|----------------|--------------------------------------------------------|
| `INA219_ENABLED` | Enable or disable the INA219 Usermod | `false` | `true`, `false` |
| `INA219_SDA_PIN` | I2C data pin (SDA) | `8` | See options below for available GPIO pins. |
| `INA219_SCL_PIN` | I2C clock pin (SCL) | `9` | See options below for available GPIO pins. |
| `INA219_I2C_ADDRESS` | I2C address of the INA219 sensor | `0x40` | See options below for available addresses. |
| `INA219_CHECK_INTERVAL` | Interval for checking sensor values (seconds) | `5` | Any positive integer |
| `INA219_CONVERSION_TIME` | ADC conversion time (12-bit, 16-bit, etc.) | `BIT_MODE_12` | See options below for available modes. |
| `INA219_DECIMAL_FACTOR` | Number of decimal places for current and power readings | `3` | See options below for decimal places. |
| `INA219_SHUNT_RESISTOR` | Value of the shunt resistor in ohms | `0.1` | Any positive float value matching your INA219 resistor |
| `INA219_CORRECTION_FACTOR` | Correction factor for measurements | `1.0` | Any positive float value |
| `INA219_MQTT_PUBLISH` | Publish sensor data to MQTT | `false` | `true`, `false` |
| `INA219_MQTT_PUBLISH_ALWAYS` | Always publish values, regardless of change | `false` | `true`, `false` |
| `INA219_HA_DISCOVERY` | Enable Home Assistant discovery for sensors | `false` | `true`, `false` |

### Options for `INA219_CONVERSION_TIME`

The `conversionTime` parameter can be set to the following ADC modes:

| Value | Description |
|-------------------|----------------------------|
| `BIT_MODE_9` | 9-Bit (84 µs) |
| `BIT_MODE_10` | 10-Bit (148 µs) |
| `BIT_MODE_11` | 11-Bit (276 µs) |
| `BIT_MODE_12` | 12-Bit (532 µs) |
| `SAMPLE_MODE_2` | 2 samples (1.06 ms) |
| `SAMPLE_MODE_4` | 4 samples (2.13 ms) |
| `SAMPLE_MODE_8` | 8 samples (4.26 ms) |
| `SAMPLE_MODE_16` | 16 samples (8.51 ms) |
| `SAMPLE_MODE_32` | 32 samples (17.02 ms) |
| `SAMPLE_MODE_64` | 64 samples (34.05 ms) |
| `SAMPLE_MODE_128` | 128 samples (68.10 ms) |

### Options for `INA219_DECIMAL_FACTOR`

The `decimalFactor` parameter can be set to:

| Decimal Places | Value | Example |
|----------------|-------|------------------|
| 0 | 0 | 100 |
| 1 | 1 | 100.0 |
| 2 | 2 | 100.00 |
| 3 | 3 | 100.000 |

### Options for `INA219_I2C_ADDRESS`

The `i2cAddress` parameter can be set to the following options:

| Address | Description | Value |
|---------------------|------------------------------------|---------|
| `0x40` | 0x40 - Default | 0x40 |
| `0x41` | 0x41 - A0 soldered | 0x41 |
| `0x44` | 0x44 - A1 soldered | 0x44 |
| `0x45` | 0x45 - A0 and A1 soldered | 0x45 |

### Options for `INA219_SDA_PIN` and `INA219_SCL_PIN`

The `SDA` and `SCL` pins can be set to any valid and unused GPIO pin, with defaults as follows:

- **Default SDA Pin**: `8`
- **Default SCL Pin**: `9`

Example GPIO pin values for configuration:

| GPIO Pin | Description |
|----------|--------------|
| `8` | Default SDA |
| `9` | Default SCL |
| Other GPIO pins are available, depending on hardware.

## Usage

1. Include this usermod in your WLED project by adding `#define USERMOD_INA219` to the `my_config.h` file.

2. **Dependencies**
These libraries must be added under `lib_deps` in your `platformio.ini` (or `platform_override.ini`):
- `wollewald/INA219_WE@~1.3.8` (by [wollewald](https://github.com/wollewald/INA219_WE))
- `Wire`

3. Configure the parameters in the web interface or via the JSON config file.

4. Monitor your energy consumption through the WLED interface or via MQTT.

5. Optional to predefine options:

#define INA219_ENABLED false
#define INA219_SDA_PIN 8
#define INA219_SCL_PIN 9
#define INA219_I2C_ADDRESS 0x40
#define INA219_CHECK_INTERVAL 5
#define INA219_CONVERSION_TIME BIT_MODE_12
#define INA219_DECIMAL_FACTOR 3
#define INA219_SHUNT_RESISTOR 0.1
#define INA219_CORRECTION_FACTOR 1.0
#define INA219_MQTT_PUBLISH false
#define INA219_MQTT_PUBLISH_ALWAYS false
#define INA219_HA_DISCOVERY false

## Energy Calculation

- **Total Energy** is calculated continuously.
- **Daily Energy** resets after 24 hours.
- **Monthly Energy** resets after 30 days.

To reset daily or monthly energy calculations, you can implement corresponding functions within your main application.

## Dependencies

Ensure you have the required libraries installed:

- [INA219_WE](https://github.com/wollewald/INA219_WE)
Binary file added usermods/INA219/img/homeassistant.png
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
Binary file added usermods/INA219/img/info.png
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
Binary file added usermods/INA219/img/usermod_settings.png
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
Loading