Notifications
You must be signed in to change notification settings - Fork 757
New issue
Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.
By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.
Already on GitHub? Sign in to your account
Return to Zero not considering limits when Z-axis reversed #2303
Comments
Thanks for the feedback. The first fix might be to make it possible to set safety height to zero - basically to disable it. To fix this we need to handle another edge case where some controllers work in positive machine coordinate space which puts the machine zero at lower front left corner. It might be solvable due to this #2301 (comment) but it will require some work. |
FYI
I also work in XY positive and Z negative space... I think a lot of CNC
routing/lasering machines do the same...
Disabling it removes a safety feature, could a relative move be an
option? It would be necessary to check if it doesn't cross the limits
though, but being close to zero in negative space could be considered
safe to move imo...
…---
Paul
|
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Version
2.0.20
Hardware / Firmware
GRBL 1.1
What happened
I might be doing something wrong, but I encountered this:
After Homing, when machine is at X0Y0Z0, if you press return to zero, it causes a limit-alarm because it wants to move to the safety height set in options. The safety height can only be set >1 (default 5).
I know returning to Zero right after homing is an unusual scenario, but consider POS X100Y100Z-4, it still would cause a limit-alarm with default safety height.
Having the safety height is a good feature, but it would be nice if it considered the limits.
Verbose output (excerpt):
Grbl 1.1f ['$' for help]
Grbl for ARM32
Version:ARM32 V2.6
$0 = 10 (step pulse,usec)
$1 = 25 (step idle delay,msec)
$2 = 0 (stepport invert mask)
$3 = 4 (dirport invert mask)
$4 = 0 (stepenable invert,bool)
$5 = 1 (lims pin invert,bool)
$6 = 1 (probe pin invert,bool)
$H
ok
<Idle|WPos:0.000,0.000,0.000,0.000|Bf:35,254|FS:0,0|Pn:RHS|WCO:0.000,0.000,0.000,0.000>
<Idle|WPos:0.000,0.000,0.000,0.000|Bf:35,254|FS:0,0|Pn:RHS|Ov:100,100,100>
<Idle|WPos:0.000,0.000,0.000,0.000|Bf:35,254|FS:0,0|Pn:RHS>
G21G90 G0Z1 // It wants to go to Z1, but my Z is inverted: $3 = 4 (dirport invert mask)
G90 G0 X0 Y0
G90 G0 Z0
ok
<Run|WPos:0.000,0.000,0.211,0.000|Bf:33,254|FS:228,0|Pn:RHS>
[MSG:Check Limits]
Error while processing response : An unexpected command was completed by the controller.
An unexpected error was detected: (ALARM:3) Reset while in motion. Machine position is likely lost due to sudden halt. Re-homing is highly recommended.
[MSG:Check Limits]
Grbl 1.1f ['$' for help]
Grbl 1.1f ['$' for help]
Grbl for ARM32
Version:ARM32 V2.6
How to reproduce
Invert Z-axis, set safety height to 5, move to POS X100Y100Z-4, press Return to Zero.
Operating System
WIN10 22H2
Anything else
No response
The text was updated successfully, but these errors were encountered: