Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Can not Connect Sunnyboy 1600TL-10 #39

Open
Rokoonl opened this issue Jan 31, 2024 · 1 comment
Open

Can not Connect Sunnyboy 1600TL-10 #39

Rokoonl opened this issue Jan 31, 2024 · 1 comment

Comments

@Rokoonl
Copy link

Rokoonl commented Jan 31, 2024

Dear reader,
I am trying to connect my Sunnyboy 1600TL-10 inverter to Homey, but it is not found by the SMA app you created. Manually entering the IP address is also unsuccessful. As far as I know the default port hasn't changed, but I have enabled port 501 Udp and tcp in my modem just to be sure. no results unfortunately. What could be wrong? the inverter is behind a repeater, but that shouldn't matter, right? I like to hear from you.

Kind regards,
Rob

@ricott
Copy link
Owner

ricott commented Jan 31, 2024

Hi!

The standard port for the SMA inverters is 502.
Modbus is by default off, you need to enable it in the inverter using the installer login.

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment