Values sent to Emoncms with Node

Following values are sent to Emoncms and displayed as Node 30 with Key from 1-20 and 30-35

  • 1 = AC_IN_V

  • 2 = AC_IN_HZ

  • 3 = AC_OUT_V

  • 4 = AC_OUT_HZ

  • 5 = AC_OUT_VA

  • 6 = AC_OUT_W

  • 7 = AC_OUT_LOAD_PERCENT

  • 8 = BUS_V

  • 9 = BATT_V

  • 10 = BATT_CHRG

  • 11 = BATT_CAPACITY_PERCENT

  • 12 = HEATSINK_TEMP

  • 13 = PV_I_BATT

  • 14 = PV_V

  • 15 = BATT_V_SCC

  • 16 = BATT_DISCHRG_I

  • 17 = PV Charging Power

  • 18 = Line Mode ( 0 or 1 ) Link Led Widget for visualization

  • 19 = Battery Mode ( 0 or 1 ) Link Led Widget for visualization

  • 20 = Fault Mode ( 0 or 1 ) Link Led Widget for visualization

  • 30 = Year for displaying lastest update

  • 31 = Month

  • 32 = Day

  • 33 = Hour

  • 34 = Minute

  • 35 = Second

New since v 1.4.9 support for Inverter with two/three MPPT displayed as Node 31 with following Keys:

  • 1 = PV2 current A

  • 2 = PV2 volt V

  • 3 = batt volt scc2 V

  • 4 = PV power2 W

  • 5 = device status

  • 6 = AC charge current A

  • 7 = AC charge power W

  • 8 = PV3 current A

  • 9 = PV3 voltage V

  • 10 = batt volt scc3 V

  • 11 = PV power3 W

  • 12 = PV total W

  • 30 = Year for displaying lastest update

  • 31 = Month

  • 32 = Day

  • 33 = Hour

  • 34 = Minute

  • 35 = Second

  • 36 = Days since online

  • 37 = Hours since Online

  • 38 = device status

  • 39 = device status2

  • Inv1 01 Serial number

  • Inv1 02 mode

  • Inv1 09 AC Out Power

  • Inv1 11 Battery Voltage

  • Inv1 12 Battery Charge A

  • Inv1 17 TOTAL AC OUT W

  • Inv1 25 PV Input A

  • Inv1 26 Battery discharge A

  • Inv2 01 Serial number

  • Inv2 02 mode

  • Inv2 09 AC Out Power

  • Inv2 11 Battery Voltage

  • Inv2 12 Battery Charge A

  • Inv2 17 TOTAL AC OUT W

  • Inv2 25 PV Input A

  • Inv2 26 Battery discharge A

  • Inv3 01 Serial number

  • Inv3 02 mode

  • Inv3 09 AC Out Power

  • Inv3 11 Battery Voltage

  • Inv3 12 Battery Charge A

  • Inv3 17 TOTAL AC OUT W

  • Inv3 25 PV Input A

  • Inv3 26 Battery discharge A

  • Inv4 01 Serial number

  • Inv4 02 mode

  • Inv4 09 AC Out Power

  • Inv4 11 Battery Voltage

  • Inv4 12 Battery Charge A

  • Inv4 17 TOTAL AC OUT W

  • Inv4 25 PV Input A

  • Inv4 26 Battery discharge A

BMV Battery Monitor displayed as Node 20 with following Keys:

  • 1 = Battery voltage mV
  • 2 = Battery current mA
  • 3 = Instantaneous Power W
  • 4 = Consumed amp Hours mAh
  • 5 = State-of-Charge
  • 6 = Time-To-Go in minutes
  • 8 = Alarm status (ON/OFF) one for ON and zero for OFF
  • 10 = Auxiliary (starter) voltage ## only with BMV-702
  • 11 = mid point voltage in mV
  • 12 = mid point deviation
  • 25 = Relay status (ON/OFF)

Values sent to PVOutput

Following values are sent to PVOutput

  • AC_OUT_V
  • AC_OUT_W
  • PV Charging Power