accessibility: Ctrl+Home then Down arrow key go to system bar for WebView2 app #10241
Labels
accessibility
Narrator, keyboarding, UIA, etc
area-WebView
bug
Something isn't working
product-winui2
Describe the bug
Seems WinUI2 is not well-integrated with WebView2 for accessibility issue in scan mode. Ctrl+Home will move focus to the top of the webpage content, but subsequent down arrow presses will navigate to the app system bar.
try Win32 + WebView2, this issue don't repro. so this should be WinUI2 bug.
Steps to reproduce the bug
Launch the sample app https://github.com/MicrosoftEdge/WebView2Samples/tree/main/GettingStartedGuides/WinUI2_GettingStarted/MyUWPGetStartApp
(optional) Update WinUI2 2.8.6, WebView2 1.0.2903.40
Turn On Narrator, "Tap" to one of page elements
"Caps Lock" + "Space" to turn on scan mode
Press Ctrl + Home to move to the top of the content.
Use the down arrow key to start navigating the content.
=> hear "MyUWPGetStartApp" from system bar
expect => the next element of the page content
Expected behavior
Actual:
After pressing Ctrl+Home, the screen reader first moves focus to the top of the webpage content, but subsequent down arrow presses navigate to system bar like the title bar, minimize button, maximalize button
Expected:
Focus should remain within the content after using Ctrl+Home, and down arrow navigation should continue consistently from the top of the webpage content without jumping through other elements like the system title bar.
Screenshots
No response
NuGet package version
WinUI 2 - Microsoft.UI.Xaml 2.8.2
Windows version
Windows 11 (24H2): Build 26100
Additional context
No response