Determine Meaning of ODU Type #353

Open
barndawgie opened this issue Feb 17, 2024 · 35 comments
Open

Determine Meaning of ODU Type #353

barndawgie opened this issue Feb 17, 2024 · 35 comments
Labels
enhancement New feature or request

Comments

@barndawgie
Copy link
Member

We should determine the meaning of ODU Type and then spec it as a text_sensor/enum instead of int.

See #345.

@barndawgie barndawgie added the enhancement New feature or request label Feb 17, 2024
@justbruce
Copy link
Contributor

Please, if you have an ODU, respond with

  1. the value of ODU Type
  2. your Model number [used to determing what series of unit] , and
  3. whether it is an Air Conditioner or Heat Pump.

@barndawgie
Copy link
Member Author

Please, if you have an ODU, respond with

  1. the value of ODU Type

  2. your Model number [used to determing what series of unit] , and

  3. whether it is an Air Conditioner or Heat Pump.

I put a note in Discord asking folks to comment here with that info.

@johncarey70
Copy link

johncarey70 commented Feb 18, 2024

  1. ODU Type 0
  2. RA18AZ36AJVCA
  3. Air Conditioner

  1. ODU Type 0
  2. RA2036AJVCB
  3. Air Conditioner

@franc6
Copy link

franc6 commented Feb 18, 2024

  1. ODU Type 0
  2. UA2036AJVCB
  3. Air Conditioner

@justbruce
Copy link
Contributor

justbruce commented Feb 19, 2024

We should determine the meaning of ODU Type and then spec it as a text_sensor/enum instead of int.

See #345.

As the data gathers, what is your suggested method for converting this to a text sensor/enum?
I looked at docs and tried to find examples, but nothing jumps out at me.

@derekatkins
Copy link

derekatkins commented Feb 20, 2024

My ODU Type says "Unknown". But it's also not "running" per se.
It's an AC.
I'll go outside at some point to determine the model number and update this comment.
ETA: t is a Classic Plus Series, High Efficiency Air Conditioner, Econet Enabled. Model Number RA1760AJ2CB

@justbruce
Copy link
Contributor

My ODU Type says "Unknown". But it's also not "running" per se. It's an AC. I'll go outside at some point to determine the model number and update this comment. ETA: t is a Classic Plus Series, High Efficiency Air Conditioner, Econet Enabled. Model Number RA1760AJ2CB

Is it powered on right now? I know it is seems a dumb question but lots of folks pull the disconnect on A/C units in the winter.......

@derekatkins
Copy link

Is it powered on right now? I know it is seems a dumb question but lots of folks pull the disconnect on A/C units in the winter.......

Yes, the breaker is turned on.

@justbruce
Copy link
Contributor

Is it powered on right now? I know it is seems a dumb question but lots of folks pull the disconnect on A/C units in the winter.......

Yes, the breaker is turned on.

Hmm. Interesting. Do you happen to know the Software Version of the Unit?.....

This is the first one I'm aware of that reports Unknown.

@derekatkins
Copy link

Hmm. Interesting. Do you happen to know the Software Version of the Unit?.....

This is the first one I'm aware of that reports Unknown.

According to the data in HA:

image

@justbruce
Copy link
Contributor

justbruce commented Feb 21, 2024

Oh..... This looks like one of the new 2 speed units [not the 3 speed that the 17-series used to be]. I wonder if they changed this datapoint name/deleted it when they changed everything else, too.

Installed very recently, or not?

@derekatkins
Copy link

derekatkins commented Feb 21, 2024 via email

@justbruce
Copy link
Contributor

Could be. I posted some verbose data captures in the discord hvac dev channel. Although I admit those are from before I added the ODU config. I won't be able to acquire another dump until Thursday.

I'm not on Discord [by choice], so I guess someone else will have the fun of parsing those..

:-)

@fireheadman
Copy link

fireheadman commented Feb 21, 2024

See attached for esphome logs (might be something in there....??)
logs_rheem-hvac_logs.txt

Strange I am not seeing the software version for ODU in my entities, could have sworn it was there before.
I do have this though...
Mine is a 2-Stage 5 ton unit
image

@barndawgie
Copy link
Member Author

See attached for esphome logs (might be something in there....??)

logs_rheem-hvac_logs.txt

Strange I am not seeing the software version for ODU in my entities, could have sworn it was there before.

I do have this though...

Mine is a 2-Stage 5 ton unit

image

Are you seeing ODU Type showing as 4?

@fireheadman
Copy link

fireheadman commented Feb 21, 2024

applied the latest esphome updates, which prompted to update all devices.
now I see this...

[23:00:58][C][econet:104]:   Datapoint ODUSWVER: text value (value: AC-2SHP-03-01-02)
[23:00:58][C][econet:104]:   Datapoint ODUSWVER: text value (value: AC-2SHP-03-01-02)

image

@fireheadman
Copy link

fireheadman commented Feb 21, 2024

What is the OCU Type Datapoint called? I am looking in the logs for "type" and there is a lot of parse through...

[fireheadman@templar Downloads 5784]$ grep TYPE logs_rheem_hvac.txt | sort -u
[23:00:53][I][econet:307]:   CMP_TYPE : 0.000000
[23:00:57][C][econet:100]:   Datapoint CMP_TYPE: float value (value: 0.000000)
[23:01:04][C][econet.sensor:026]:   Sensor has datapoint ID ODU_TYPE
[23:01:09][I][econet:198]:   CMP_TYPE
[23:01:09][I][econet:307]:   CMP_TYPE : 0.000000
[23:01:17][I][econet:198]:   CMP_TYPE
[23:01:17][I][econet:307]:   CMP_TYPE : 0.000000
[23:01:20][I][econet:198]:   ODU_TYPE
[23:01:26][I][econet:198]:   CMP_TYPE
[23:01:34][I][econet:307]:   CMP_TYPE : 0.000000
[23:01:42][I][econet:198]:   CMP_TYPE
[23:01:42][I][econet:307]:   CMP_TYPE : 0.000000
[23:01:51][I][econet:198]:   CMP_TYPE
[23:01:51][I][econet:307]:   CMP_TYPE : 0.000000
[23:01:52][I][econet:198]:   ODU_TYPE
[23:01:58][I][econet:198]:   CMP_TYPE
[23:01:58][I][econet:307]:   CMP_TYPE : 0.000000
[23:02:06][I][econet:198]:   CMP_TYPE
[23:02:07][I][econet:307]:   CMP_TYPE : 0.000000
[23:02:14][I][econet:198]:   CMP_TYPE
[23:02:15][I][econet:307]:   CMP_TYPE : 0.000000
[23:02:22][I][econet:198]:   ODU_TYPE
[23:02:31][I][econet:198]:   CMP_TYPE
[23:02:31][I][econet:307]:   CMP_TYPE : 0.000000
[23:02:40][I][econet:307]:   CMP_TYPE : 0.000000
[23:02:47][I][econet:198]:   CMP_TYPE
[23:02:47][I][econet:307]:   CMP_TYPE : 0.000000
[23:02:52][I][econet:198]:   ODU_TYPE
[23:02:56][I][econet:307]:   CMP_TYPE : 0.000000
[23:03:04][I][econet:307]:   CMP_TYPE : 0.000000
[23:03:12][I][econet:198]:   CMP_TYPE
[23:03:12][I][econet:307]:   CMP_TYPE : 0.000000
[23:03:20][I][econet:198]:   CMP_TYPE
[23:03:20][I][econet:307]:   CMP_TYPE : 0.000000
[23:03:22][I][econet:198]:   ODU_TYPE

And if I grep -i type, then I have a lot more

[fireheadman@templar Downloads 5786]$ grep -i TYPE logs_rheem_hvac.txt | sort -u | wc -l
     407

@justbruce
Copy link
Contributor

What is the OCU Type Datapoint called? I am looking in the logs for "type" and there is a lot of parse through...

[fireheadman@templar Downloads 5784]$ grep TYPE logs_rheem_hvac.txt | sort -u
[23:00:53][I][econet:307]:   CMP_TYPE : 0.000000
[23:00:57][C][econet:100]:   Datapoint CMP_TYPE: float value (value: 0.000000)
[23:01:04][C][econet.sensor:026]:   Sensor has datapoint ID ODU_TYPE
[23:01:09][I][econet:198]:   CMP_TYPE
[23:01:09][I][econet:307]:   CMP_TYPE : 0.000000
[23:01:17][I][econet:198]:   CMP_TYPE
[23:01:17][I][econet:307]:   CMP_TYPE : 0.000000
[23:01:20][I][econet:198]:   ODU_TYPE
[23:01:26][I][econet:198]:   CMP_TYPE
[23:01:34][I][econet:307]:   CMP_TYPE : 0.000000
[23:01:42][I][econet:198]:   CMP_TYPE
[23:01:42][I][econet:307]:   CMP_TYPE : 0.000000
[23:01:51][I][econet:198]:   CMP_TYPE
[23:01:51][I][econet:307]:   CMP_TYPE : 0.000000
[23:01:52][I][econet:198]:   ODU_TYPE
[23:01:58][I][econet:198]:   CMP_TYPE
[23:01:58][I][econet:307]:   CMP_TYPE : 0.000000
[23:02:06][I][econet:198]:   CMP_TYPE
[23:02:07][I][econet:307]:   CMP_TYPE : 0.000000
[23:02:14][I][econet:198]:   CMP_TYPE
[23:02:15][I][econet:307]:   CMP_TYPE : 0.000000
[23:02:22][I][econet:198]:   ODU_TYPE
[23:02:31][I][econet:198]:   CMP_TYPE
[23:02:31][I][econet:307]:   CMP_TYPE : 0.000000
[23:02:40][I][econet:307]:   CMP_TYPE : 0.000000
[23:02:47][I][econet:198]:   CMP_TYPE
[23:02:47][I][econet:307]:   CMP_TYPE : 0.000000
[23:02:52][I][econet:198]:   ODU_TYPE
[23:02:56][I][econet:307]:   CMP_TYPE : 0.000000
[23:03:04][I][econet:307]:   CMP_TYPE : 0.000000
[23:03:12][I][econet:198]:   CMP_TYPE
[23:03:12][I][econet:307]:   CMP_TYPE : 0.000000
[23:03:20][I][econet:198]:   CMP_TYPE
[23:03:20][I][econet:307]:   CMP_TYPE : 0.000000
[23:03:22][I][econet:198]:   ODU_TYPE

And if I grep -i type, then I have a lot more

[fireheadman@templar Downloads 5786]$ grep -i TYPE logs_rheem_hvac.txt | sort -u | wc -l
     407

The ODU Type datapoint is ODU_TYPE. I think the CMP_TYPE point is for the type of compressor, though every Econet unit Rheem/Ruud sold until very recently was advertised as having a Copeland Scroll compressor, so I haven't worked on putting the Compressor Type in, as it seemed less than useful

@justbruce
Copy link
Contributor

See attached for esphome logs (might be something in there....??)
logs_rheem-hvac_logs.txt
Strange I am not seeing the software version for ODU in my entities, could have sworn it was there before.
I do have this though...
Mine is a 2-Stage 5 ton unit
image

Are you seeing ODU Type showing as 4?

That is my reading of the logs as well. I wonder why it is showing unknown - unless something else is blocking the read? Maybe in the request_mod group? Hmm.....

@justbruce
Copy link
Contributor

applied the latest esphome updates, which prompted to update all devices. now I see this...

[23:00:58][C][econet:104]:   Datapoint ODUSWVER: text value (value: AC-2SHP-03-01-02)
[23:00:58][C][econet:104]:   Datapoint ODUSWVER: text value (value: AC-2SHP-03-01-02)

image

Would you mind taking some more logs? I have a pet theory as to why the Type is showing as UNKNOWN, and your logs after your update might help...

@justbruce
Copy link
Contributor

See attached for esphome logs (might be something in there....??)
logs_rheem-hvac_logs.txt
Strange I am not seeing the software version for ODU in my entities, could have sworn it was there before.
I do have this though...
Mine is a 2-Stage 5 ton unit
image

Are you seeing ODU Type showing as 4?

Is there a way to specify 2 addresses for a datapoint to be read from?

I'm seeing that @fireheadman has an ODU which is at the 0x500 address, and currently the substitution is set to a 0x400 address.

Is this something we need to split into a separate file?

@barndawgie
Copy link
Member Author

Is this something we need to split into a separate file?

For now it's probably best to just put in a substitution. We can add details like this to the wiki if there are known configs required for certain units (at least for now).

@derekatkins
Copy link

@justbruce --

Is there a way to specify 2 addresses for a datapoint to be read from?

I'm seeing that @fireheadman has an ODU which is at the 0x500 address, and currently the substitution is set to a 0x400 address.

Where are you seeing that this is the address of his ODU? It sounds like he has the same outdoor unit that I have.

Is this something we need to split into a separate file?

@justbruce
Copy link
Contributor

justbruce commented Feb 22, 2024

@justbruce --

Is there a way to specify 2 addresses for a datapoint to be read from?
I'm seeing that @fireheadman has an ODU which is at the 0x500 address, and currently the substitution is set to a 0x400 address.

Where are you seeing that this is the address of his ODU? It sounds like he has the same outdoor unit that I have.

Is this something we need to split into a separate file?

The logs. The SRC address for the OCOMMAND is 0x500.

If you're comfortable testing some local changes and then compile/upload, we can see if I'm right.

in the file econet_hvac_odu.yaml change odu_address: "1024" to odu_address: "1280" then compile and upload

@derekatkins
Copy link

@justbruce --

The logs. The SRC address for the OCOMMAND is 0x500.

Aha. Looks like the same for me (not surprising since we have the same unit):

[11:06:23][I][econet:161]: <<< 80.00.05.00.00.80.00.03.80.00.12.00.00.1F.01.01.00.07.00.00.4F.43.4F.4D.4D.41.4E.44.00.00.00.00.32.73 (34)
[11:06:23][I][econet:162]:   Dst Adr : 0x500
[11:06:23][I][econet:163]:   Src Adr : 0x380
[11:06:23][I][econet:164]:   Command : 31
[11:06:23][I][econet:165]:   Data    : 01.01.00.07.00.00.4F.43.4F.4D.4D.41.4E.44.00.00.00.00 (18)
[11:06:23][I][econet:253]:   ClssType: 1
[11:06:23][I][econet:261]:   OCOMMAND: 0.000000
[11:06:23][I][econet:161]: <<< 80.00.03.80.00.80.00.05.00.00.01.00.00.06.01.BF.AA (17)
[11:06:23][I][econet:162]:   Dst Adr : 0x380
[11:06:23][I][econet:163]:   Src Adr : 0x500
[11:06:23][I][econet:164]:   Command : 6
[11:06:23][I][econet:165]:   Data    : 01

If you're comfortable testing some local changes and then compile/upload, we can see if I'm right.
in the file econet_hvac_odu.yaml change odu_address: "1024" to odu_address: "1280" then compile and upload

I push changes through HA's EcoHome Add-On. So I can update my econet-hvac_furnace.html config file, but I do not not have good way to update the component files without creating a new git branch that I can point to. Is there some way to make this change as a substitution in my main config file? Worst case I could fork/branch/update, but a simple config change would be easier.

@derekatkins
Copy link

For the record, I added odu_address: "1280" to the substitutions section of my main config file and pushed the update to the my device. I am now getting more data! It is now reporting the ODU Model Number, ODU Serial Number, and ODU Type says "0" instead of "unknown".

There are still a bunch of "unknown" and "0" (or 0.0) value ODU items, but fewer than before.

@fireheadman
Copy link

fireheadman commented Feb 22, 2024

applied the latest esphome updates, which prompted to update all devices. now I see this...

[23:00:58][C][econet:104]:   Datapoint ODUSWVER: text value (value: AC-2SHP-03-01-02)
[23:00:58][C][econet:104]:   Datapoint ODUSWVER: text value (value: AC-2SHP-03-01-02)

image

Would you mind taking some more logs? I have a pet theory as to why the Type is showing as UNKNOWN, and your logs after your update might help...

Here are some logs from this morning, I have made no changes.

logs_rheem-hvac_logs.txt

For the record, I added odu_address: "1280" to the substitutions section of my main config file and pushed the update to the my device. I am now getting more data! It is now reporting the ODU Model Number, ODU Serial Number, and ODU Type says "0" instead of "unknown".

There are still a bunch of "unknown" and "0" (or 0.0) value ODU items, but fewer than before.

...And here more more logs after applying the same substitution for "1280"
logs_econet-hvac_furnace_run_1280.txt

Which shows this:
[08:11:10][I][econet:307]: ODU_TYPE : 0.000000

image

@fireheadman
Copy link

fireheadman commented Feb 22, 2024

Here is what I am showing for ODU objects reported:
This is with these substitutions: (Note: I am on propane)

substitutions:
  name: econet-hvac_furnace
  friendly_name: Rheem HVAC
  furnace_kbtus_per_m3: "88.852"
  logger_level: DEBUG
  odu_address: "1280"
packages:
  esphome-econet.esphome-econet: github://esphome-econet/esphome-econet/build-yaml/econet-hvac_furnace-esp32.yaml@main
  esphome-econet.econet-hvac-odu: github://esphome-econet/esphome-econet/econet_hvac_odu.yaml@main

image

image

@barndawgie
Copy link
Member Author

Are we pretty confident at this point that Type 0 is AC and Type 1 is Heat Pump? Are there any counter examples or other values?

@fireheadman
Copy link

I would agree with that since having it set is allowing more variables to populate with accurate data.

@justbruce
Copy link
Contributor

Are we pretty confident at this point that Type 0 is AC and Type 1 is Heat Pump? Are there any counter examples or other values?

I'm pretty confident. This is only like 10 data points, and no one else with a heat pump has yet chimed in, but I'm still pretty happy to call Type 0 AC and Type 1 HP.

@Daniel-dev22
Copy link
Collaborator

  1. ODU type 5
  2. My ODU is from 2017 timeframe doesn't report model number. I know it's an RP20 2.5ton
  3. Heat Pump

Software version: AC-VSHP-00-01-41

@justbruce
Copy link
Contributor

  1. ODU type 5

    1. My ODU is from 2017 timeframe doesn't report model number. I know it's an RP20 2.5ton

    2. Heat Pump

Software version: AC-VSHP-00-01-41

Do you happen to know what address it is at? [see issue #354 ]

@Daniel-dev22
Copy link
Collaborator

  1. ODU type 5

    1. My ODU is from 2017 timeframe doesn't report model number. I know it's an RP20 2.5ton

    2. Heat Pump

Software version: AC-VSHP-00-01-41

Do you happen to know what address it is at? [see issue #354 ]

My address is 0x400

@justbruce
Copy link
Contributor

  1. ODU type 5

    1. My ODU is from 2017 timeframe doesn't report model number. I know it's an RP20 2.5ton
    2. Heat Pump

Software version: AC-VSHP-00-01-41

Do you happen to know what address it is at? [see issue #354 ]

My address is 0x400

Well there goes my neat little 0-AC, 1-HP theory.........