In addition to the Remote Control B findings. Fan speed implementation was found to be different in remote control model WH-TA03NE/WH-TA04NE as below. Fan Speed - First 4 bits of the 7th byte (byte[6]).
|
This was referenced May 13, 2024
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Version/revision of the library used
v2.8.6/master
Describe the bug
I have two indoor units installed close together and configured to use "Remote Control A" in the first unit and "Remote Control B" in the other unit to avoid interference, as described in the user manual below.
The current codebase has hardcoded the first five bytes
0xF20D03FC01
that only allows to emulate "Remote Control A". After capturing the IR signals of "Remote Control B", it is found that the only variance is on the leading 4 bits of the 3rd byte in the 72-bits command.While the 4th byte's value is already derived by the checksum function automatically. Please help to enhance the support by enabling to specify remote type in the constructor and expose the field with getter, setter functions. Thank you.