Connection drops after a while, how to refresh it #38
Comments
If I recall correctly we had this problem before, the client should maintain token actuality in the background: https://github.com/amenzhinsky/iothub/blob/master/iotservice/client.go#L147 |
There is this stack of calls:
That is not using consistently a Go context - it is recreating in a few different places This does not allow to refresh the IoT Hub token and the effect is that having a long running process that is supposed to be constantly connected to the IoT Hub to send "could-to-device" messages does not work. This long running process stops working after around 1 hour from when it was started. I ended up working around this issue with: func (ms *myStruct) IotHubRefreshConnection(iotHubConnStr string) {
if ms.ihsClient != nil {
log.Info.Println("Closing the IoT Hub connection...")
ms.ihsClient.Close()
}
log.Printf("Connecting to the IoT Hub with: %v", iotHubConnStr)
ihQueueClient, err := iotservice.NewFromConnectionString(
iotHubConnStr,
iotservice.WithLogger(
logger.New(
logger.LevelDebug,
func(lvl logger.Level, s string) {
log.Println(fmt.Sprint("*IH-CLIENT* ", lvl.String(), " ", s))
},
),
),
)
if err != nil {
log.Error.Printf("Cannot establish the IoT Hub connection: %+v", err)
panic(err)
}
ms.ihsClient = ihQueueClient
}
func syncRefreshSchedule(ms *myStruct, iotHubConnStr string) {
for {
log.Info.Println("Wating to refresh the Iot Hub connection...")
select {
case <-time.After(10 * time.Minute):
log.Info.Println("Recurrent time to refresh the IoT Hub connection...")
ms.IotHubRefreshConnection(iotHubConnStr)
}
}
} Then in my constructor of ms.IotHubRefreshConnection(iotHubConnStr)
go syncRefreshSchedule(&ms, iotHubConnStr) This way I make sure there is always a working IoT Hub session. Even after 1 hour. |
Can you try the latest master, there was simply a defer error that closed amqp session before it tired to renew token. |
I'm creating a cloud-to-device link via AMQP with:
I can use this successfully for 1 hour or so, but then after that I start seeing:
Looks like the AMQP connection is being dropped due to inactivity or just because 1 hour is passed after it has been created. Is there any way I can avoid this? How can I specify to automatically refresh or reconnect to the IoT Hub?
I can see in here
iothub/iotservice/client.go
Line 44 in e718b48
there's this TLS option, but it's not exactly related to timeouts, that's more about extra security checks when using TLS: