You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
I am running the same structural test cases (LV passive filling) using svFSI and svFSIplus, but the results (e.g., pressure on the surface) are noticeably different. We tested several potential simulation parameters, and viscosity, the Holzapfel material model, and fiber direction seem to be leading to these differences. Structural_cases.zip
Reproduction
Running the three test cases above using svFSI and svFSIplus respectively.
Expected behavior
The two solvers give the same results.
Additional context
No response
Code of Conduct
I agree to follow this project's Code of Conduct and Contributing Guidelines
The text was updated successfully, but these errors were encountered:
Description
I am running the same structural test cases (LV passive filling) using svFSI and svFSIplus, but the results (e.g., pressure on the surface) are noticeably different. We tested several potential simulation parameters, and viscosity, the Holzapfel material model, and fiber direction seem to be leading to these differences.
Structural_cases.zip
Reproduction
Running the three test cases above using svFSI and svFSIplus respectively.
Expected behavior
The two solvers give the same results.
Additional context
No response
Code of Conduct
The text was updated successfully, but these errors were encountered: