Which Document?
[Onion Omega 2S Datasheet] (https://github.com/OnionIoT/Omega2/blob/master/Documents/Omega2S%20Datasheet.pdf)

What version?
Version 1.8

Which section can use improvement?
Page 13-15
Page 23

What's currently lacking

  1. What is LINK3 and LINK4 at GPIO 39&40? There's no mention of these anywhere else.
  2. According to the datasheet the Omega 2S has 1 Ethernet interface. In the descriptions there's PHY Port #0/1/2/3 mentioned on different GPIO's. As far as I know, there should only be #0.
  3. On Page 23, Recommended PCB Footprint dimension 2,71 should be 2,70; it's off by 0,01mm.

Describe the proposed improvement
Please review these points and correct the datasheet where needed.

Screenshots
Correct dimensions as shown in CAD software.